Lenze L-force 9400 Series - Page 204

Lenze L-force 9400 Series
583 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Multi-axis controllers
Control terminals
5
204
EDS94SPP101 EN 7.1
Terminal X3 Labelling Description
GA GND analog signals
AO1 Analog output 1
AO2 Analog output 2
A1+ Analog input 1 +
A1- Analog input 1 -
A1- Analog input 1 -
A1R Terminating resistor for ±20mA
A2+ Analog input 2 +
A2- Analog input 2 -
SSP94000X3
Shield connection: Fix the shield with EMC wire clamp.
Terminal data
Conductor cross-section Tightening torque
[mm
2
] [AWG] [Nm] [lb-in]
Flexible
0.2 ... 2.5
24 ... 12 Spring terminal
With wire end
ferrule
Note!
If the control terminals are completely wired, we recommend to use a cable
cross-section of max. 0.75 mm
2
to save space. The mechanical cover can then
be attached.