Single-axis controllers
Rated data (devices for 400/500V mains)
Operation at rated mains voltage 230 V
4
50
EDS94SPP101 EN 7.1
4.3.2 Operation at rated mains voltage 230 V
Device size 1 ... 6
Basis of the data
Mains Voltage Voltage range Frequency range
U
LN
[V] U
LN
[V] f[Hz]
3/PE AC 230 180-0%...264+0% 45-0%...65+0%
2/PE DC 325 260-0%...370+0% -
Mains current at I
aN
Output power Motor power
(typical)
with external
mains choke
without external
mains choke
U, V, W 4pol.ASM
Type I
LN
[A] I
LN
[A] S
aN
[kVA] P
aN
[kW] P
aN
[hp]
E94ASxE0024 1.5 2.1 0.5 0.18 0.25
E94ASxE0034 2.5 3.5 0.9 0.37 0.5
E94ASxE0044 3.9 5.5 1.4 0.75 1
E94ASxE0074 7.0 9.9 2.5 1.5 2
E94ASxE0134 12.0 16.8 4.7 3 4
E94ASxE0174 15.0 21.0 5.9 4 5.5
E94ASxE0244 20.5 29.0 8.4 5.5 7.5
E94ASxE0324 - 29.0 11.5 7.5 10
E94ASxE0474 - 43.0 16.9 11 15
E94ASxE0594 - 54.0 21.2 15 20
Device size 7
Basis of the data
Mains Voltage Voltage range Frequency range
U
LN
[V] U
LN
[V] f[Hz]
3/PE AC 230 180-0%...264+0% 45-0%...65+0%
Mains current at I
aN
Output power Motor power
(typical)
with external
mains choke
without external
mains choke
U, V, W 4pol.ASM
Type I
LN
[A] I
LN
[A] S
aN
[kVA] P
aN
[kW] P
aN
[hp]
E94ASxE0864 - 79.0 30.8 22 29
E94ASxE1044 - 95.0 37.3 30 40