EasyManua.ls Logo

Lenze L-force 9400 Series

Lenze L-force 9400 Series
583 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DC-bus operation
Rated data
DC fuses
8
325
EDS94SPP101 EN 7.1
8.4.4 DC fuses
When using the busbar system (X109/X110), fuse the busbar system in the installation
backplane to protect the DC-bus connection. The DC-bus connection is protected against
damage through a DC earth fault or short circuit in a device.
Controller (with installation backplane)/DC fuse assignment
Type
Rated value Type Size Number per
[A] (SIBA) [mm] or size backplane
Multi Drives
E94AMxE0024
E94AMxE0034
E94AMxE0044
16 EFSAR0016ARHN 14 x 51
1
E94AMxE0074
E94AMxE0094
40 EFSAR0040ARHN 14 x 51
E94AMxE0134
E94AMxE0174
E94AMxE0244
E94AMxE0324
100 EFSAR0100ARHN
NH00
(screwable)
Single Drives (can be retrofitted with E94AZJA0xx busbar mounting set))
E94ASxE0024
E94ASxE0034
16 EFSAR0016ARHN 14 x 51
1
E94ASxE0044
E94ASxE0074
40 EFSAR0040ARHN 14 x 51
E94ASxE0134
E94ASxE0174
E94ASxE0244
100 EFSAR0100ARHN
NH00
(screwable)
Tab. 8-6
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com