EasyManua.ls Logo

Lenze L-force 9400 Series - Page 266

Lenze L-force 9400 Series
583 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Regenerative power supply modules
Rated data (devices for 400/500V mains)
Operation at rated mains voltage 230 V
7
266
EDS94SPP101-7.1
7.3.1 Operation at rated mains voltage 230 V
Basis of the data
Mains Voltage Voltage range Frequency range
U
LN
[V] U
LN
[V] f[Hz]
3/PE AC 230 180-0%...264+0% 45 ... 65
Input data (on the supply side)
Voltage Frequency Current [A]
Number of
phases
[V] [Hz] max. +45 °C c max. +55 °C c
E94ARNE0134
In motor mode
230 50/60 26 19.5 3
In generator mode
230 50/60 13 9.8 3
E94ARNE0244
In motor mode
230 50/60 47 35 3
In generator mode
230 50/60 23.5 17.6 3
c Temperature in the control cabinet
Voltage Continuous input power
Type [V] S
L
[kVA]
E94ARNE0134
In motor mode
230 10.3
In generator mode
230 5.2
E94ARNE0244
In motor mode
230 18.7
In generator mode
230 9.4
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com

Table of Contents

Other manuals for Lenze L-force 9400 Series

Related product manuals