Loading...
Regenerative power supply modules
Rated data (devices for 400/500V mains)
Operation at rated mains voltage 400 V
7
268
EDS94SPP101-7.1
7.3.2 Operation at rated mains voltage 400 V
Basis of the data
Mains Voltage Voltage range Frequency range
U
LN
[V] U
LN
[V] f[Hz]
3/PE AC 400 320-0%...440+0% 45 ... 65
Input data (on the supply side)
Voltage Frequency Current [A]
Number of
phases
[V] [Hz] max. +45 °C c max. +55 °C c
E94ARNE0134
In motor mode
400 50/60 26 19.5 3
In generator mode
400 50/60 13 9.8 3
E94ARNE0244
In motor mode
400 50/60 47 35 3
In generator mode
400 50/60 23.5 17.6 3
c Temperature in the control cabinet
Voltage Continuous input power
Type [V] S
L
[kVA]
E94ARNE0134
In motor mode
400 18.0
In generator mode
400 9.0
E94ARNE0244
In motor mode
400 32.5
In generator mode
400 16.3
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com