7.6.4 Connecting busbars
SSP94PN201
Fig. 7-9 Example: connecting busbars to DC power supply module
Proceed as follows to connect the busbars:
1. If devices of the interconnected system have already been in operation:
Ensure that the power supply system is switched off by checking the voltage at the
supply terminals.
If necessary, switch off the power supply and wait at least 3 minutes.
2. Loosen the busbar screws but do not remove them completely.
3. Push the busbars as far as possible to the left towards the adjacent busbar.
Ensure that there is good contact to the adjacent busbar.
4. Tighten the busbar screws.
Tightening torque: 3.2 ... 3.5 Nm (28 ... 31 lb-in).
5. Screw all components onto the mounting plate.
Tightening torque: 3.4 Nm (30 lb-in).