Single-axis controllers
Rated data (devices for 400/500V mains)
Overview
4
48
EDS94SPP101 EN 7.1
Output data
Voltage Frequency
1)
Current [A]
Number of
phases
Type [V] [Hz] max. +45 °C
c
max. +55 °C
c
E94ASxE0024 0 - 230/400/500 0 - 480 1.5/1.5/1.3 1.1/1.1/1.0 3
E94ASxE0034 0 - 230/400/500 0 - 480 2.5/2.5/2.2 1.9/1.9/1.7 3
E94ASxE0044 0 - 230/400/500 0 - 480 4/4/3.5 3/3/2.6 3
E94ASxE0074 0 - 230/400/500 0 - 480 7/7/6.1 5.3/5.3/4.6 3
E94ASxE0134 0 - 230/400/500 0 - 480 13/13/11.4 9.8/9.8/8.6 3
E94ASxE0174 0 - 230/400/500 0 - 480 16.5/16.5/14.4 12.4/12.4/10.8 3
E94ASxE0244 0 - 230/400/500 0 - 480 23.5/23.5/20.6 17.6/17.6/15.5 3
E94ASxE0324 0 - 230/400/500 0 - 599 32.0/32.0/28.0 24.0/24.0/21.0 3
E94ASxE0474 0 - 230/400/500 0 - 599 47.0/47.0/41.0 35.3/35.3/30.8 3
E94ASxE0594 0 - 230/400/500 0 - 599 59.0/59.0/51.6 44.3/44.3/38.7 3
E94ASxE0864 0 - 230/400/500 0 - 599 86.0/86.0/75.3 64.5/64.5/56.4 3
E94ASxE1044 0 - 230/400/500 0 - 599 104/104/91.0 78.0/78.0/68.3 3
E94ASxE1454 0 - 400/500 0 - 599 145/145 131/131 3
E94ASxE1724 0 - 400/500 0 - 599 172/172 155/155 3
E94ASxE2024 0 - 400/500 0 - 599 202/202 182/182 3
E94ASxE2454 0 - 400/500 0 - 599 245/245 221/221 3
E94ASxE2924 0 - 400/500 0 - 599 292/292 263/263 3
E94ASxE3664 0 - 400/500 0 - 599 366/366 329/329 3
E94ASxE4604 0 - 400/500 0 - 599 460/460 414/414 3
E94ASxE5724 0 - 400/500 0 - 599 572/572 515/515 3
E94ASxE6354 0 - 400/500 0 - 599 635/635 572/572 3
E94ASxE6954 0 - 400/500 0 - 599 695/695 626/626 3
c Temperature in the control cabinet
1)
The limitation to 599 Hz does not apply to the ”servo control” modes (see C00006=1or2).Generallyapplies:the
output frequency is limited to 1/8 of the selected chopper f requency (see C00018).
Note!
The indicated output voltage will not be reached under certain operating
conditions.
ƒ Output power in the maximum range
ƒ High switching frequencies
ƒ Use of mains filters or mains chokes
ƒ Mains supply with high impedance (U
k
>5%)