EasyManua.ls Logo

Lenze m500-P Series

Lenze m500-P Series
58 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Electrical installation
EMC−compliant wiring
Brake connection to terminal
6
31
Lenze ¯ BA 33.0008 ¯ 5.0
6.3.2 Brake connection to terminal
Contact Meaning Additional specifications
~ AC−excited brake (rectifier) Connection to L1 − mains
~
1
2
3
4
5
6
-
~
~
+
Connection to N − mains
+ Brake connection
Brake connection
Switching contact, DC switching
BD1 / 1BD1 / 5 Brake, DC operated DC connection
BD2 / 1BD2 / 6
MS1 / 2S1 / 32 Brake microswitch, release control Two−way switch
MS2 / 2S2 / 33 NC contact
MS4 / 2S3 / 34 NO contact
MS1 / 3S1 / 35 Brake microswitch, wear control Two−way switch
MS2 / 3S2 / 36 NC contact
MS4 / 3S3 / 37 NO contact
MS1 Brake microswitch, manual release Two−way switch
MS2 NC contact
MS4 NO contact