Appendix10
56
Lenze ¯ BA 33.0008 ¯ 5.0
Technical data in compliance with ordinance (EC) No. 640/2009
No. m500−P/m550−P motors
1
h
100%
[%] 82.5 85.0 85.0 87.0 88.0 88.6 89.6 90.4 91.4 92.1
92.6 93 93.6 93.6 93.9 94.2
h
75%
[%] 83.9 84.1 84.9 87.3 87.2 88.3 90.3 90.5 91.2 91.9 93.2 93.2 93.7 93.7 94.2 93.9
h
50%
[%] 81.7 81.5 82.4 86 85.8 87.3 88.6 89.7 89.8 90.9 93.0 92.9 93.4 93.4 93.4 93.1
2 IE3 IE3 IE3 IE3 IE3 IE3 IE3 IE3 IE3 IE3 IE3 IE3 IE3 IE3 IE3 IE3
3 For year of manufacture and week of manufacture see nameplate: ^ LEERER MERKER
4 Lenze Drives GmbH, Breslauer Straße 3, D−32699 Extertal, GERMANY, HR Lemgo B 6478
5 Motor code M55AP
080M04
M55AP
090M04
M55AP
090L04
M55AP
100M04
M55AP
100L04
M55AP
112M04
M55AP
132M04
M50AP
132M04
M55AP
132L04
M50AP
132L04
M55AP
160M04
M50AP
160M04
M55AP
160L04
M50AP
160L04
M55AP
180M04
M50AP
180M04
M55AP
180L04
M50AP
180L04
M55AP
180V04
M50AP
180V04
M55AP
200M04
M50AP
200M04
M55AP
225M04
M50AP
225M04
M55AP
225L04
M50AP
225L04
6 Number of poles 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4
7 P
rated
[kW] 0.75 1.1 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 30 37 45
8 f
r
[Hz] 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50
9 V
rated
[V] 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400
10 n
r
[rpm] 1450 1444 1442 1452 1449 1453 1460 1477 1478 1470 1483 1480 1478 1478 1483 1482
11 Information regarding the disposal: ^ 12
12
i) Permissible installation height: ^ 19
ii) Permissible ambient air temperatures: ^ 19
Permissible ambient air temperatures: ^ 19
iii) Not relevant, since motors are not liquid−cooled.
iv) Maximum operating temperature: 155 C (temperature class F)