General UL notes
WARNING!
UL marking
Use 75 °C copper wire only, except for control circuits.
Maximum conductor size is AWG14.
Cord connected drives are for use only in NFPA 79 applicaons.
Overload protecon: 125 % of rated FLA
Integral solid state short circuit protecon does not provide branch circuit protecon. Branch circuit
protecon must be provided in accordance with the Naonal Electrical Code and any addional local
codes.
CAUTION - Risk of electric shock. Do not disconnect under load.
Marquage UL
Uliser exclusivement des conducteurs en cuivre 75 °C, sauf pour la pare commande.
Taille de conducteur maximale : AWG14.
Les entraînements avec câble d’alimentaon sont desnés exclusivement à des applicaons conformes à
la norme NFPA 79.
Protecon contre les surcharges : homologuée pour 125 % du courant assigné à pleine charge.
La protecon staque intégrée n’ore pas la même protecon qu’un disjoncteur. Une protecon par
disjoncteur externe doit être fournie, conformément au Naonal Electrical Code et aux règlementaons
locales applicables.
ATTENTION ! Risque de choc électrique. Ne pas débrancher l’équipement sous charge.
Single drive connecon according to UL 61800-5-1
L1
3/N/PE AC 400/480 V
L1
L2
L3
N
PE
F1 … F3
L2
L3
SELV/PELV
DC 24 V
(+19.2 … +28.8 V)
5.6k
5.6k
R
b
M
3~
Rb1 Rb2
V
U
W
+
+
X3
X4
+
1 2 3
BD1BD2
X2
1 2 3
4
X1
1 2 3
4
X5
max. 50 mA
X6
GND
-I
DI1DI2
n. c.
5.6k
GND
-O
DO1DI324V
DC
AC
Q
400
1
23
4 1
23
4
Rb1 Rb2
X4
R
b
Rb1 Rb2
390
L1
F1 … F3
L2
L3
+
+
X3
Q
2
3
A
B
1
+
GND is bridged if the "DI/DO−GND bridged" version is specied on the nameplate.
Electrical installaon
Mains connecon
Connecon according to UL
57