EasyManua.ls Logo

Lenze Smart Motor m300 - Technical Data; Standards and Operating Conditions; Conformities;Approvals; Protection of Persons and Device Protection

Lenze Smart Motor m300
76 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data
Standards and operang condions
Conformies/approvals
Conformity
CE 2014/35/EU Low-Voltage Direcve
2014/30/EU EMC Direcve (reference: CE-typical drive system)
EAC TR TC 004/2011 Eurasian conformity: safety of low voltage equipment
TP TC 020/2011 Eurasian conformity: electromagnec compability of
technical means
Approval
CCC GB Standard 12350-2009
cULus UL 61800-5-1 for USA and Canada (requirements of the CSA 22.2 No. 14)
Industrial Control Equipment, Lenze File No. E132659
Protecon of persons and device protecon
Degree of protecon
IP55 EN 60529
Type 4 indoor only
Type 12
NEMA 250 Dependent on the conguraon
Insulaon resistance
Overvoltage category III EN 61800-5-1 Site altude 0 … 2000 m above sea level
Overvoltage category II EN 61800-5-1 Site altude more than 2000 m above sea level:
External measures for compliance with the overvoltage
category II are required, e.g. connecon of an isolang
transformer upstream ,connecon of an overvoltage
protecon system upstream
Protecve insulaon of control circuits
Safe mains isolaon via double/reinforced
insulaon for digital inputs and outputs
EN 61800-5-1 Site altude 0 … 2000 m above sea level
Upstream connecon of overvoltage
protecon device
EN 61800-5-1 Site altude more than 2000 m above sea level:
Addional external separang measures are necessary for
purposes of safe separaon.
Protecve measures against
Short circuit EN 61800−5−1 To a limited extent, fault acknowledgement necessary
Earth fault EN 61800−5−1 To a limited extent, fault acknowledgement necessary
Overvoltage Yes
Motor stalling Yes
Overtemperature of motor
I
2
xt-monitoring
Leakage current
> 3.5 mA AC, > 10 mA DC EN 61800-5-1 Please observe regulaons and safety instrucons!
Equipotenal bonding Addional M5 thread with terminal at the terminal box for
connecng another PE cable (up to max. 6 mm
2
)
Total fault current
Residual current operated switch 30 mA,
Type B
In TN power supply systems
Cyclic mains switching
3 mes a minute, max. 20 mes per hour Mains switching 3 mes in one minute must be followed by
a pause of 9 minutes.
Starng current
5.6 A mains power-on current
Technical data
Protecon of persons and device protecon
72

Table of Contents

Other manuals for Lenze Smart Motor m300

Related product manuals