Parameter set management
Parameter Value Comment
Designaon Delivery Seng range
PIN --- [0000 ... 9999] PIN for the protecon against unauthorised
alteraon of the parameter set (0 = no
protecon).
Alteraon of "PIN" sets "new PIN" to the
same value.
The parameters can also be read without a
PIN.
New PIN --- [0000 ... 9999] Future PIN for protecon against
unauthorised alteraon of the parameter set.
Standard sengs
Parameter Value Comment
Designaon Delivery Seng range
Parameter set name --- [Text] File name of the parameter set without le
extension *.lsm
Output speed 1 depending on the
order
[-2600/i ... -500/i] rpm
[0] rpm
[500/i ... 2600/i] rpm
CCW rotaon: < 0 rpm
STOP: 0 rpm
CW rotaon: > 0 rpm
Lenze Smart motor with gearbox: The rao i
is taken into account in the calculaon of the
output speed.
Output speed 2
Output speed 3
Output speed 4
Output speed 5
Acceleraon me [0.0 ... 20.0] s
Acceleraon me t
1
of the ramp generator
from 0 rpm to n
max
[2600/i] rpm
Deceleraon me Deceleraon me t
2
of the ramp generator
from n
max
[2600/i] rpm to 0 rpm
Energy-saving funcon [O] Opmized for:
•
High dynamic performance
•
Maximum starng torque and torque
•
High speed accuracy
[On] Reduced energy absorpon in paral load
operaonal range.
Approx. 50 % of the maximum starng torque
are available.
Diagnoscs
Parameter Value Comment
Designaon Delivery Seng range
Peak load of the drive --- [0 … 250] % Last peak value of the medium thermal load
(maximum value in the last mains switching
cycle)
From rmware version 03.00.00.00
Peak load of the brake
resistor
--- [0 … 250] % Last peak value of the thermal ulisaon of
the brake resistor (maximum value in the last
mains switching cycle)
From rmware version 03.00.00.00
Meters
Parameter Value Comment
Designaon Delivery Seng range
Elapsed-hour meter --- [0 ... 596523] h Total me of "Motor rotang"
Operang‐hour meter --- [0 ... 596523] h Total me of "mains ON"
Commissioning
62