SMD
Frequency Inverter: Basic I/O
with CANopen 0.25kW... 4.0kW
Operating Instructions
(13466185)

Questions and Answers

  • C
    Craig GreenSep 3, 2025
    What to do for Controller overtemperature on Lenze Inverter?
    • K
      Kristen OliverSep 3, 2025
      If the Lenze Inverter displays 'Controller overtemperature', it means the controller is too hot inside. To resolve this, reduce the controller load and improve cooling.
  • B
    Brent GibsonSep 3, 2025
    What does current limit reached mean on Lenze Inverter?
    • S
      snowtannerSep 3, 2025
      If the Lenze Inverter shows 'Current limit reached', it indicates a controllable overload. This is managed automatically, as described in C22.
  • T
    thomasbrendaSep 4, 2025
    How to fix No access to code on Lenze Inverter?
    • M
      Mrs. Martha Murphy MDSep 4, 2025
      If the Lenze Inverter displays 'No access to code', it means that changes can only be made when the controller is in OFF or 1nh. To proceed, set terminal 28 to LOW or inhibit by serial link.
  • S
    Stephanie SmithSep 4, 2025
    What to do if Lenze Inverter shows Data on EPM not valid?
    • C
      Christopher GonzalezSep 4, 2025
      If the Lenze Inverter indicates 'Data on EPM not valid', it means the data is not valid for the controller. To resolve this, either use an EPM providing valid data or load the Lenze setting.
  • R
    Richard YatesSep 5, 2025
    What causes Single phase fault on Lenze Inverter?
    • C
      carolynburchSep 5, 2025
      If the Lenze Inverter displays 'Single phase fault', it indicates that a mains phase has been lost. To resolve this, check the mains voltage.
  • J
    Jose BraySep 5, 2025
    What does EPM error mean on Lenze Inverter?
    • J
      Jamie GrantSep 6, 2025
      If the Lenze Inverter displays 'EPM error', it means the EPM is either missing or defective. To fix this, power down the system and replace the EPM.
  • H
    Hannah WongSep 6, 2025
    How to fix Loss of 4-20 mA reference on Lenze Inverter?
    • J
      jeremy67Sep 6, 2025
      If the Lenze Inverter indicates 'Loss of 4-20 mA reference', it means the 4-20 mA signal is below 2 mA (C34 = 4). To resolve this, check the signal and signal wire.
  • M
    Michael MendezSep 6, 2025
    What does external error mean on Lenze Inverter?
    • S
      Stephanie GonzalezSep 7, 2025
      If the Lenze Inverter displays 'External error', it means the digital input “TRIP set” is active. To resolve this, remove the external error.
  • K
    Kim AtkinsSep 7, 2025
    How to troubleshoot Remote keypad fault on Lenze Inverter?
    • M
      meghanjohnsonSep 7, 2025
      If the Lenze Inverter shows 'Remote keypad fault', it means the remote keypad is disconnected. To resolve this, check the remote keypad connections.

Summary

About These Instructions

Scope of Delivery

Details items included with the inverter.

Important Notes

Critical information regarding product receipt and checks.

Safety Information

General Safety Precautions

Overall safety guidelines for handling and operation.

Application as Directed

Specifies intended use and compliance with directives.

Installation Safety

Guidelines for safe mechanical and electrical installation.

Operation Safety

Safety considerations during the operation of the inverter.

Pictographs and Warnings

Explains symbols and signal words used in the manual.

Technical Data

Standards and Application Conditions

Lists relevant standards and environmental operating conditions.

Product Ratings

Details electrical specifications and output current ratings.

Installation

Mechanical Installation

Covers physical mounting and dimensions of the inverter.

Electrical Installation

Details wiring, EMC requirements, and connection diagrams.

Commissioning

Parameter Setting Overview

Explains how to set and adjust operating parameters.

Electronic Programming Module (EPM)

Describes the EPM for storing and managing parameter settings.

Parameter Menu Structure

Details the codes, names, and functions of various parameters.

CANopen Mapping Details

Defines how data is mapped for CANopen communication.

RPDO Mapping Details

Specifies the mapping of Receive PDO data.

TPDO Mapping Details

Specifies the mapping of Transmit PDO data.

Quick CAN Setup

Guides through the initial setup for CAN communication between controllers.

Troubleshooting and Fault Elimination

Status Indicators and Basic Faults

Explains status codes and common basic operational faults.

Specific Error Codes and Causes

Lists specific error codes, their causes, and remedies.

CAN Communication Faults

Addresses faults related to CAN communication timeouts and initialization.

Circuit and Overload Faults

Covers faults related to short circuits, overloads, and voltage issues.

Lenze SMD Specifications

General IconGeneral
Product seriesSMD
CategoryDC Drives
Field currentUp to 2 A
Control modeSpeed, torque, position
ProtectionOvercurrent, overvoltage, overtemperature