EasyManua.ls Logo

Lenze AC Tech SC Series User Manual

Lenze AC Tech SC Series
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
SCF Series Drives
Modbus Communications Reference Guide
Question and Answer IconNeed help?

Do you have a question about the Lenze AC Tech SC Series and is the answer not in the manual?

Lenze AC Tech SC Series Specifications

General IconGeneral
BrandLenze
ModelAC Tech SC Series
CategoryDC Drives
LanguageEnglish

Summary

Safety Information

General Safety Guidelines

Covers general, application, and installation safety precautions for drive controllers.

Introduction to Modbus

SCF Drive Setup & Operation

Start/Stop, Speed, and Parameter Operations

Step-by-step guide for serial control of start/stop, speed, and parameter changes.

SCF Drive Control Registers

SCF Programming Parameters

Quick Start Instructions

Drive Control Operations

Instructions for Start/Stop control, drive unlocking, and setting manual mode for network operation.

Basic Drive Modbus Commands

Basic commands for STOP, START, direction changes, and speed control via Modbus registers.

Safety Information Details

Electrical Connection and Operation Safety

Modbus Communication Details

Universal Registers

Drive Control & Communication

SCF Drive Control Registers Overview

Describes SCF Drive Control Registers, their order, R/W status, message format, and units.

Drive Status Registers Overview

Explains reading Registers #24-29 for drive status, covering command speed and actual speed.

SCF Parameter List - Initial Parameters

Lists initial SCF drive parameters: Line Voltage, Carrier Frequency, Start/Stop Method, Speed Source, and Outputs.

SCF Parameter List - Input/Output Parameters

Lists SCF drive parameters for TB-13A/B/C Input, TB-15 OC Output, and Control settings.

SCF Parameter List - Serial and Timing Parameters

Lists SCF drive parameters: Serial Link, Units Editing, Rotation, Acceleration/Deceleration, DC Brake.

SCF Parameter List - Frequency and Protection Parameters

Lists SCF drive parameters: Frequency limits, Current Limit, Overload, Boost, Slip Compensation, Preset Speeds.

SCF Parameter List - Scaling and Address Parameters

Lists SCF drive parameters: Skip Frequency, Bandwidth, Speed/Load Scaling, Accel/Decel #2, Serial Address.

SCF Parameter List - Version and Fault History

Lists SCF drive parameters: Password, Clear History, Program Selection, Fault History, Software Version.

Related product manuals