EasyManuals Logo

Lenze SMVector User Manual

Lenze SMVector
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background imageLoading...
Page #12 background image
11
SV01N_13418587 EN/DE/ES/FR/IT/PT
Installation
3 Installation
3.1 Dimensions and Mounting
WARNING!
Drives must not be installed where subjected to adverse environmental conditions such as: combustible, oily, or
hazardous vapors; corrosive chemicals; excessive dust, moisture or vibration; direct sunlight or extreme temperatures.
3.1.1 NEMA 1 (IP31) Models < 30HP (22kW)
b2
b1
b
a
a1
c
s1 s1
s2
s2
Mounting Screws
4 x #10
18 lb-in
4 x M5
20 Nm
()
Type
a
in (mm)
a1
in (mm)
b
in (mm)
b1
in (mm)
b2
in (mm)
c
in (mm)
s1
in (mm)
s2
in (mm)
m
lb (kg)
G1
ESV251~~~~~B; ESV371~~~~~B
ESV751~~~~~B
3.90 (99) 3.12 (79) 7.48 (190) 7.00 (178) 0.24 (6) 4.35 (111) 0.6 (15) 2.0 (50) 2.0 (0.9)
G2
ESV112~~~~~B; ESV152~~~~~B
ESV222~~~~~B
3.90 (99) 3.12 (79) 7.52 (191) 7.00 (178) 0.26 (7) 5.45 (138) 0.6 (15) 2.0 (50) 2.8 (1.3)
G3 ESV402~~~~~B 3.90 (99) 3.12 (79) 7.52 (191) 7.00 (178) 0.30 (8) 5.80 (147) 0.6 (15) 2.0 (50) 3.2 (1.5)
H1 ESV552~~~~~B; ESV752~~~~~B 5.12 (130) 4.25 (108) 9.83 (250) 9.30 (236) 0.26 (7) 6.30 (160) 0.6 (15) 2.0 (50) 6.0 (2.0)
J1
ESV113~~~~~B; ESV153~~~~~B
ESV183~~~~~B; ESV223~~~~~B
6.92 (176) 5.75 (146) 12.50 (318) 11.88 (302) 0.31 (8) 8.09 (205) 0.6 (15) 2.0 (50) 13.55 (6.15)
Conduit Hole Dimensions Type
N
in (mm)
P
in (mm)
P1
in (mm)
Q
in (mm)
S
in (mm)
Q
N
Q
P
S
P1
G1 1.84 (47) 1.93 (49) .70 (18) 1.00 (25) .88 (22)
G2 1.84 (47) 3.03 (77) .70 (18) 1.00 (25) .88 (22)
G3 1.84 (47) 3.38 (86) .70 (18) 1.00 (25) .88 (22)
H1 2.46 (62) 3.55 (90) .13 (3) 1.38 (35)
1.13 (29)
.88 (22)
J1 3.32 (84) 4.62 (117) .73 (19) 1.40 (36)
1.31 (33)
.88 (22)
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.actechdrives.com - Email: info@actechdrives.com

Other manuals for Lenze SMVector

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze SMVector and is the answer not in the manual?

Lenze SMVector Specifications

General IconGeneral
Protection ClassIP20
Overload Capacity150% for 60 seconds
Communication OptionsCANopen, Profibus DP
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short Circuit
Control MethodSensorless Vector
Ambient Temperature-10°C to +40°C