42
SV01N_13418587 EN/DE/ES/FR/IT/PT
Commissioning
4.5.6  Network Parameters
Code Possible Settings
IMPORTANT
No. Name Default Selection
p400
Network Protocol 0  Not Active This parameter setting is based upon the network 
or I/O module that is installed.
1  Remote Keypad
2  Modbus RTU
3 CANopen
4 DeviceNet
5 Ethernet
6 Profibus
7 Lecom-B
8  I/O Module
p401
Module Type Installed 0 0  No Module Installed Module type format: 0xAABC; Drive Display: 
AA.B.C
AA = Module Type
B = Major revision
C = minor revision
1  Basic I/O (0x0100, 1.0.0)
2  RS485/Rem. Keypad (0x0200, 2.0.0)
3  CANopen (0x0300, 3.0.0)
11  PROFIBUS (0x1100, 11.0.0)
12  Ethernet (0x1200, 12.0.0)
P402
Module Status 0 0  Not Initialized
1  Initialization: Module to EPM
2  Initialization: EPM to Module
3 Online
4  Failed Initialization Error
5  Time-out Error
6  Initialization Failed Module type mismatch P401
7  Initialization Error Protocol selection mismatch P400
P403
Module Reset 0 0  No Action Returns module parameters 401…499 to the 
default values shown in the manual
1  Reset parameters to default values
P404
Module Timeout Action 3 0  No Fault Action to be taken in the event of a Module/
Drive Time-out.
Time is fixed at 200ms
STOP is by the method selected in P111.
1  STOP (see P111)
2  Quick Stop
3  Fault (F_ntF)
P405
Current Network Fault 0  No Fault
1 F.nF1 NetIdle Mode
2 F.nF2 Loss of Ethernet I/O connection
3 F.nF3 Network Fault
4 F.nF4 Explicit Message Timeout
5 F.nF5 Overall Network Timeout
6 F.nF6 Overall Explicit Timeout
7 F.nF7 Overall I/O Message Timeout
P406
Proprietary Manufacturer specific
p407 … P499
Module Specific Parameters
Refer to the Communications Reference Guide 
specific to the network or I/O module installed.