PostScript
4-96
On boolean Designates if the communication channel is On and able to receive and
send data. Supported values are:
True Data is sent and processed.
False Data is lost.
PCLSmartSwitch boolean Supported values are:
True PCL SmartSwitch is On.
False PCL SmartSwitch is Off.
For more information, see Using SmartSwitch on page 2-1.
PortLocation string (Read-only) Designates the physical location of the port related to the
parameter set. Supported values are:
Standard Port
Option Slot 1
Option Slot 2
Option Slot 3
PSSmartSwitch boolean Supported values are:
True PS SmartSwitch is On.
False PS SmartSwitch is Off.
For more information, see Using SmartSwitch on page 4-1.
Type name (Read-only) Always returns the value of /Communications.
Device Parameters for the Communication Device %IR%, %IR_A%, %IR_B%, %IR_C%, %IR_D%
(%IR_NV% and %IR_Pending% contain the same parameters)
DelayedOutputClose boolean Selects how the printer manages the port at the end of each print job.
Supported values are:
True An end-of-file message is not sent until the current job and all
preceding jobs finish printing.
False An end-of-file message is sent as soon as a job finishes
executing in the interpreter, whether or not that job has
finished printing.
This value is set independently for each port.
Enabled boolean (Read-only)
Supported values are:
True
False
Filtering name Indicates if the input needs further filtering before the data can be correctly
processed. Supported values are:
InterpreterBased
None
HasNames boolean (Read-only) Always returns False.
Table 4-21: PostScript Emulation Device Parameters (Continued)