5 Remove the spring (B) and the fuser gear (C).
BC
MPF solenoid removal
1 Remove the left cover. See “Left cover removal” on page 168.
2 Remove the main drive gearbox. See “Main drive gearbox removal” on page 169.
3 Disconnect the MPF solenoid cable from the controller board.
4 Remove the screw (A).
4514