Diagnostic aids 3-97
7462
Go Back
Previous
Next
2. Loosen the M4 screw (A) on the right below.
3. Turn the skew adjustment screw (B) (to the left, below) appropriately - clockwise for negative skew and
counterclockwise for positive skew.
Note: Each full turn of the adjustment screw yields .5 mm of skew correction. The maximum adjustment is
three turns for clockwise movement of the screw, and four turns for counterclockwise movement.
4. After skew has been corrected, tighten the M4 screw above. Assembly is reverse of the removal
procedures.
Note: If the bracket above is aligned with the alignment hole in the ADF frame, the duplex LED assembly is
parallel with its roller.