Repair information 4-65
7462
Go Back
Previous
Next
ADF duplex CCD assembly removal (X654, X656, and X658)
CAUTION: When you see this symbol, there is a danger from hazardous voltage in the area of the
product where you are working. Unplug the product before you begin, or use caution if the product
must receive power in order to perform the task.
1. Remove the ADF duplex CCD scan glass assembly. See “ADF duplex CCD scan glass assembly
removal (X654, X656, and X658)” on page 4-64.
2. Disconnect the CCD harness from the top of the ADF unit assembly.
3. Remove the skew adjustment locking screw (A), the skew adjustment screw (B), and the spring.
A
B