Plug-in control
43
GA 05.139/1.02 - 06/99
4.3.6 Total view of the menu
Pump Standstill
Power Supply OK
Start Command
Enter
Threshold
60 °C
Enter
Threshold
10.0 A
Enter
Threshold
300 Hz
Enter
Actual PZ12
Actual PVW24
Actual PVW13
Bearing Temp.
Actual Frequency
Analog Output
Motor Current
Enter
Enter
Option Relay 3
Power Supply OK
Enter
Option Relay 4
Pump Standstill
Enter
Option Relay 2
Start Command
Vent
Programming menu
Stop
Data to Eeprom?
Prog=yes Esc=no
Prog
Ready
00.0 A 0000 Hz
Esc
Data are stored
in the EPROM
To exit the programming menu
Ready
0.0 A 0 Hz
Enter
Freq. Setpoint
480 Hz
Enter
Operation Hours
0.00 h
Enter
Motor Temp.
50 °C
Enter
Converter Temp.
40 °C
Enter
Bearing Temp.
50 °C
Enter
Actual PVW 13
10%
Enter
Actual PVW 24
10%
Enter
Actual PZ 12
5%
Enter
Power
400 W
Enter
Not Active
Actual Value TMS
63 °C
Enter
Not Active
Cooling Temp.
20 °C
Enter
Basic menu
Via X14
Purge ON
Set Pump
Enter
Normal Operation
95 %
Enter
Max. Accel. time
800 s
Enter
Pump Type
MAG 1600/2000 CT
Enter
Set TMS
Enter
TMS Setpoint
60 °C
Enter
Set Purge/Vent
Enter
Purge/Vent
Purge OFF
Enter
Option P/V
Option 1
Enter
or
Main menus
Software Version
104.xx
Enter
German
TMS OK
No Purge Gas
No Cooling Water
Frequency
Set Converter
Enter
Motor Current
Option Relay 1
Bearing Temp.
Scale factor
1.0 x
Enter
Freq. Setpoint
Analog Input 2
No Function
Enter
Start Delay
0 s
Enter
Display
English
Enter
Bus Address
0
Enter
Key Function
Esc Returns to the operating display from the storage procedure
without storage.
Returns to the operating display from any point of the basic
menu.
Mon No function
Prog Selects the programming menu from the operating display.
Confirms to store changed parameters to the EEPROM
Enter Switches forward to the next submenu
Start Starts the pump (only possible if there is no fault).
The start key is only active if the user is in the basic menu
or in the operating display.
Stop Stops the pump
Returns to the operating display from the programming menu.
Acknowledges a failure after the cause of the failure has
been removed.
+ Increases a parameter value or proceeds to the next option.
Lowers a parameter value or returns to the previous option.
< Selects the programming menu from the operating display.
Switches back to the last main menu.
> Selects the programming menu from the operating display.
Switches forward to the next main menu.
or
or
or
Not active at MAG W 2010 CHT