4.3.1 Basic menu
Menu item Description Adjustable value / option Ac-
cess
min. max. stan- Unit
value value dard
Ready Operating display - - - - -
Freq. Setpoint Sets the speed for operation 150 480 480 Hz r/w
!! Every change is directly written
into the pump’s data storage
and is valid immediately!!
Operation Hours Total operating hours of the pump actual value h r
Motor Temp. Motor temperature actual value °C r
Converter Temp. Temperature of the power actual value °C r
electronic
Bearing Temp. Temperature of the magnetic actual value °C r
bearing
Actual Value TMS Temperature of the Temperature actual value °C r
Management System
Cooling Temp. Cooling water temperature actual value °C r
Actual PVW 13 Rotor displacement in the
magnetic bearing actual value % r
plane VW13
Actual PVW 24 Rotor displacement in the
magnetic bearing actual value % r
plane VW24
Actual PZ 12 Rotor displacement in the
magnetic bearing actual value % r
axis Z12
Power Power consumption of the drive actual value W r
Software Version Actual software version actual value - r
Plug-in control
40
GA 05.139/1.02 - 06/99
Ready
0.0 A 0 Hz
Enter
Freq. Setpoint
480 Hz
Enter
Operation Hours
0.00 h
Enter
Motor Temp.
50 °C
Enter
Converter Temp.
40 °C
Enter
Bearing Temp.
50 °C
Enter
Actual PVW 13
10%
Enter
Actual PVW 24
10%
Enter
Actual PZ 12
5%
Enter
Power
400 W
Enter
Not Active
Actual Value TMS
63 °C
Enter
Not Active
Cooling Temp.
20 °C
Enter
r (read) = value can only be read
r /w (read/write) = value can be read and written