28 GA02411_002_C0 - 10/2016 - © Leybold
1.2.2 Technical Data of the SP-Guard Monitoring System
(only for certain pump versions, see Section 1.4)
Operating voltage 24 V DC
Power rating 5 W
Type of protection IEC 60259 IP 65
PLC outputs Level PLC High approx. VCC -1 V
PLC Low approx. GND +1
Current, continuous < 40 mA
max. power loss 5 W (all switching outputs added)
Current rating 40 mA
1.2.3 Technical Data of the Solenoid Gas Ballast Valve
(only for certain pump versions, see Section 1.4)
Permissible admission pressure 1 bar (g)
Media temperature max. 80 °C
Operating medium filtered, dry air on nitrogen,
filter mesh 40 Ìm
Operating voltage 24 V DC +/- 10% normally closed
Power rating during operation 6 W
Power rating when being energised 80 W
Type of protection IP 65 acc. to IEC 60259
Cable diameter 6-7 mm
Electrical connector with Varistor Bürkert, type 8376 acc. to DIN 43650
Form A