24 _ Air-to-Water Heat Pump
Part 1. Monobloc Unit
9. Performance Data
9.1 Cooling Operation
LWT : Leaving Water Temperature
TC: Total Capacity
PI: Power Input (kW)
Notice: Measuring procedure follows EN-14511
Notice: Above table values may not be matched according to installation condition
Outdoor
Temperature
LWT 7℃ LWT 10℃ LWT 13℃ LWT 15℃ LWT 18℃ LWT 20℃ LWT 22℃
TC PI TC PI TC PI TC PI TC PI TC PI TC PI
20℃ DB 3.65 0.85 4.11 0.91 4.57 0.97 4.96 1.04 5.38 1.10 5.76 1.16
30℃ DB 4.15 1.32 4.35 1.34 4.70 1.45 5.13 1.39 5.24 1.37 5.47 1.35
35℃ DB 3.82 1.42 4.16 1.47 4.48 1.50 4.85 1.51 4.99 1.38 5.17 1.49 5.37 1.54
40℃ DB 3.64 1.58 3.86 1.62 4.24 1.66 4.50 1.68 4.59 1.54 4.76 1.57 4.94 1.60
45℃ DB 3.07 1.70 3.40 1.72 3.74 1.76 4.06 1.78 4.40 1.81 4.54 1.79 4.68 1.77
Outdoor
Temperature
LWT 7℃ LWT 10℃ LWT 13℃ LWT 15℃ LWT 18℃ LWT 20℃ LWT 22℃
TC PI TC PI TC PI TC PI TC PI TC PI TC PI
20℃ DB 5.11 1.22 5.76 1.31 6.40 1.40 6.95 1.49 7.53 1.58 8.06 1.67
30℃ DB 5.80 1.90 6.09 1.93 6.58 2.08 7.18 2.00 7.34 1.97 7.65 1.95
35℃ DB 5.34 2.05 5.83 2.11 6.28 2.16 6.80 2.17 7.00 2.00 7.23 2.14 7.51 2.22
40℃ DB 5.09 2.28 5.40 2.33 5.93 2.39 6.30 2.42 6.42 2.21 6.66 2.25 6.92 2.30
45℃ DB 4.29 2.44 4.77 2.48 5.24 2.53 5.68 2.56 6.15 2.61 6.35 2.57 6.55 2.54
Outdoor
Temperature
LWT 7℃ LWT 10℃ LWT 13℃ LWT 15℃ LWT 18℃ LWT 20℃ LWT 22℃
TC PI TC PI TC PI TC PI TC PI TC PI TC PI
20℃ DB 6.57 1.62 7.40 1.74 8.23 1.86 8.94 1.98 9.68 2.10 10.37 2.21
30℃ DB 7.46 2.52 7.83 2.55 8.46 2.76 9.24 2.65 9.43 2.62 9.84 2.58
35℃ DB 6.87 2.71 7.50 2.80 8.07 2.86 8.74 2.88 9.00 2.65 9.30 2.83 9.66 2.94
40℃ DB 6.54 3.02 6.94 3.09 7.63 3.17 8.10 3.21 8.25 2.93 8.56 2.99 8.90 3.04
45℃ DB 5.52 3.23 6.13 3.29 6.74 3.35 7.30 3.40 7.91 3.45 8.17 3.41 8.42 3.37
Model: AHBW056A0 [HM051M]
Model: AHBW076A0 [HM071M]
Model: AHBW096A0 [HM091M]