26 _ Air-to-Water Heat Pump
Part 1. Monobloc Unit
9. Performance Data
LWT : Leaving Water Temperature
TC: Total Capacity
PI: Power Input (kW)
Notice: Measuring procedure follows EN-14511
Notice: Above table values may not be matched according to installation condition
Model: AHBW128A0 [HM123M]
Model: AHBW148A0 [HM143M]
Model: AHBW168A0 [HM163M]
Outdoor
Temperature
LWT 7℃ LWT 10℃ LWT 13℃ LWT 15℃ LWT 18℃ LWT 20℃ LWT 22℃
TC PI TC PI TC PI TC PI TC PI TC PI TC PI
20℃ DB 12.80 3.49 13.98 3.55 15.14 3.62 15.95 3.66 15.60 3.16 16.70 3.34
30℃ DB 12.33 4.00 13.39 4.06 14.45 4.15 15.16 4.20 15.20 3.95 15.85 3.89
35℃ DB 11.94 4.46 13.02 4.56 14.10 4.66 14.33 4.56 14.50 4.00 14.98 4.27 15.57 4.43
40℃ DB 11.45 4.72 12.07 4.91 13.34 5.06 13.70 5.04 13.30 4.42 13.79 4.51 14.34 4.59
45℃ DB 8.59 4.55 9.92 4.65 10.24 4.18 10.46 3.87 12.75 5.21 13.16 5.15 13.57 5.08
Outdoor
Temperature
LWT 7℃ LWT 10℃ LWT 13℃ LWT 15℃ LWT 18℃ LWT 20℃ LWT 22℃
TC PI TC PI TC PI TC PI TC PI TC PI TC PI
20℃ DB 13.40 3.97 14.64 4.04 15.88 4.12 16.20 4.05 16.68 3.71 17.85 3.92
30℃ DB 12.70 4.44 13.80 4.51 14.89 4.60 15.62 4.67 16.25 4.63 16.95 4.56
35℃ DB 12.30 4.95 13.23 5.00 14.15 5.05 14.77 5.06 15.50 4.69 16.02 5.01 16.64 5.20
40℃ DB 11.79 5.24 12.26 5.39 13.39 5.49 13.71 5.54 14.21 5.18 14.75 5.28 15.32 5.39
45℃ DB 8.59 4.55 9.92 4.65 10.24 4.18 10.46 3.87 13.63 6.11 14.07 6.03 14.51 5.96
Outdoor
Temperature
LWT 7℃ LWT 10℃ LWT 13℃ LWT 15℃ LWT 18℃ LWT 20℃ LWT 22℃
TC PI TC PI TC PI TC PI TC PI TC PI TC PI
20℃ DB 11.23 2.92 13.43 3.57 15.56 4.22 16.98 4.65 18.66 4.85 19.78 4.98
30℃ DB 13.75 4.83 14.94 4.91 16.12 5.01 16.92 5.08 18.05 5.17 18.81 5.23
35℃ DB 12.50 5.17 14.26 5.36 15.35 5.48 15.72 5.33 16.10 5.07 17.72 5.62 18.33 5.67
40℃ DB 11.99 5.64 13.22 5.77 14.52 5.95 15.04 6.02 15.53 5.57 16.18 5.64 16.83 5.71
45℃ DB 8.59 4.55 9.92 4.65 10.24 4.18 10.46 3.87 11.20 3.90 12.15 3.93 12.82 3.95