EasyManuals Logo

LG HM031M User Manual

LG HM031M
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #34 background imageLoading...
Page #34 background image
9. Performance Data
Air-to-Water Heat Pump _ 31
Part 1. Monobloc Unit
9.3 NF PAC Test Result
Humidification Correction Factor for Heating Operation
The capacity table does not consider reduction in capacity when humidification effect in the outdoor temperature below zero.
The capacity values considered these factors, in other words the integrated heating capacity values, can be obtained as
follow :
Formula
Integrated Heating capacity = A
Value given in table of capacity characteristics = B
Integrated correction factor for humidification effect = C
A=B x C
Correction factor for finding intergrated Heating capacity
Model
Outdoor
Temperature
LWT 35℃ LWT 45℃
Sound Power
Level[dB(A)]
TC PI TC PI
AHBW036H0
-7°C DB
57.0
7°C DB
AHBW056A0
-7°C DB
64.3
7°C DB
AHBW076A0
-7°C DB
64.3
7°C DB
AHBW096A0
-7°C DB
64.3
7°C DB
AHBW126A0
-7°C DB
66.9
7°C DB
AHBW146A0
-7°C DB
66.9
7°C DB
AHBW166A0
-7°C DB
66.9
7°C DB
AHBW128A0
-7°C DB
66.9
7°C DB
AHBW148A0
-7°C DB
66.9
7°C DB
AHBW168A0
-7°C DB
66.9
7°C DB
0.95
1.00
0.95
1.00
0.95
1.00
0.95
0.97
0.95
1.00
0.95
1.00
0.95
1.00
0.95
1.00
0.95
1.00
0.95
1.00
1.00
1.00
1.10
1.00
1.10
1.00
1.10
1.00
0.95
1.00
0.95
1.00
1.03
1.00
0.95
1.00
0.95
1.00
1.00
1.00
0.95
1.05
0.95
0.98
0.95
1.00
0.95
0.99
0.95
1.00
0.95
1.00
0.95
1.00
0.95
0.99
0.95
1.00
0.95
1.00
1.00
0.94
1.05
1.00
1.05
1.00
1.10
1.05
0.95
1.00
0.95
1.00
1.05
0.96
0.95
1.00
0.95
1.00
1.00
1.00

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LG HM031M and is the answer not in the manual?

LG HM031M Specifications

General IconGeneral
BrandLG
ModelHM031M
CategoryHeat Pump
LanguageEnglish

Related product manuals