3. Door opening sensing circuit
(1) GR-L267BV(T)R, BNRY (Refer to appendix)
(2) GR-L267BV(T)RA (Refer to appendix)
(3) GR-L267BV(T,S)PA (Refer to appendix)
Since door switches (A) and (B) are interconnected, if either fails, the other will not respond properly.
If either switch fails, the light will not come on.
EXPLANATION FOR MICOM CIRCUIT
- 42 -
Closing 5 V ( A - B , C - D . Switch at both ends are at OFF status)
Opening 0 V ( A - B , C - D . Switch at both ends are at ON status)
Measuring part
IC1 (MICOM) No. (44, 45) / (45, 46) / (47, 48) Pin