EasyManua.ls Logo

LG LSC26905TT - Temperature compensation and temperature compensation circuit

LG LSC26905TT
145 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1-10. Temperature compensation and temperature compensation circuit
1. Temperature compensation in freezer and refrigerator
(1) GR-L267BV(T)R (Refer to appendix) (2) GR-L267BV(T)RA (Refer to appendix)
(3) GR-L267BV(T,S)PA
(Refer to appendix)
u Temperature compensation table by adjustment value (difference value against current temperature)
Ex) If you change compensation resistance at the refrigerator (RCR1) from 10 k (current resistance) to 18 k (modified
resistance), the temperature at the refrigerator will increase by +1°C[+1.8°F].
EXPLANATION FOR MICOM CIRCUIT
- 52 -
Temperature compensation at refrigerator
Temperature compensation at freezer
Temperature compensation at refrigerator
Temperature compensation at freezer
Freezer Refrigerator
Resistance value Temperature Resistance value Temperature Remarks
(RCF1) compensation (RCR1) compensation
180 k +5 °C [+9°F] 180 k +2.5 °C [+4.5°F] Warmer
56 k +4 °C [+7.2°F] 56 k +2.0 °C [+3.6°F]
33 k +3 °C [+5.4°F] 33 k +1.5 °C [+2.7°F]
18 k +2 °C [+3.6°F] 18 k +1.0 °C [+1.8°F]
12 k +1 °C [+1.8°F] 12 k +0.5 °C [+0.9°F]
10 k 0 °C [0°F] 10 k 0 °C [0°F]
Reference temperature
8.2 k -1 °C [-1.8°F] 8.2 k -0.5 °C [-0.9°F]
5.6 k -2 °C [-3.6°F] 5.6 k -1.0 °C [-1.8°F]
3.3 k -3 °C [-5.4°F] 3.3 k -1.5 °C [-2.7°F]
2 k -4 °C [-7.2°F] 2 k -2.0 °C [-3.6°F]
470 -5 °C [-9°F] 470 -2.5 °C [-4.5°F] Cooler