- 78 -
1) Abnormal Freezer Sensor Error
CHECKING FLOW RESULT & SERVICE ACTION
1) Remove the Cover sensor.
2) Cut sensor and stripe terminals.
3) Make a short in striped terminals.
4) Maker measurement.
4
5
Result
Service Action
YES
Explain to costumer
Replace Main PCB
ERROR
Normal
Same
Different
Proceed acord the
displayed error
NO.
6
Resistance Values are according to Temperature
Chart table?
Result
Service Action
0 Ù
OFF
Change the sensor
Replace Product
Short
Open
Result
Service Action
YES
NO
Replace Main PCB
Replace Sensor
Normal
Sensor
Abnormal
Sensor