Page #166 background imageLoading...
Page #166 background image
Vacuum & Charge of Refrigerant
By default, the product was charged of refrigerant.
Vacuum and refrigerant charge, If there is leak refrigerant.
1. Vacuum
To work of vacuum action. when the leak of refrigerant.
Vacuum pump
(0.5 ~ 1 HP)
Lo Hi
Manifold valve
Pressure
gauge
Open
Close
SVC Port
Manifold gauge
When selecting a vacuum, you should select one which is capable of achieving 0.2 Torr of
ultimate vacuum.
Degree of vacuum is expressed in Torr, micron,mmHg, and Pascal (Pa). The units correlate as
follows:
Unit
Standard atmospheric
pressure
Perfect vacuum
Gauge Pressure Pa 0 -1.033
Absolute Pressure Pa 1.033 0
Torr Torr 760 0
Micron Micron 760 000 0
mmHg mmHg 0 760
Pa Pa 1 013.33 0
COMMISSIONING
166
ENGLISH

Table of Contents