COMBO
WM3677 COMBO Page 37 of 68 TRAINING MANUAL
DISPENSER
1. Remove the top plate.
2. Remove the dispenser.
3. Remove the two screws from
the front of the dispenser.
4. Remove the clamp and the
large hose on the back of
the dispenser.
5. Leave the small feed hoses on
the dispenser.
6. Disconnect the electrical
connectors on the valves. The
connector and wire colors will
aid upon reassembly.
7. Remove the two screws that
secure the cold water valve
assembly.
8. Reassembly is the reverse
of these steps.
Valve Assembly Wire/Connector Chart
(#) (Connector) (Wire) (Dispenser valve opened)
1 BLUE Yellow and Black (dryer water - cold)
2 WHITE White and Black (main wash - cold)
3 BLUE Gray and Black (pre-wash - cold)
4 RED Blue and Black (hot input)
5 WHITE Orange and Black (bleach - cold)
(To dispense softener, both the main and pre-wash solenoids are opened.