COMBO
WM3677 COMBO Page 56 of 68 TRAINING MANUAL
Dryer Repair, continued
7. Release the clamp and remove
the dryer water supply hose at
the solenoid end.
Lift out the condenser duct
assembly. Be careful to avoid
damaging the boot.
8. Leave the hose in the duct end.
If this comes out, you must first
fit the gasket into the hole in the
duct, with the smaller side of the
gasket facing the duct. Then
insert the hose connector and
rotate it 90° to lock it in place.
9. Dryer reassembly is the reverse
of these steps.
Test and diagnostic procedures are shown on pages 33~34.