Lighthouse Worldwide Solutions ApexR5 User Manual

Default Icon
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Lighthouse Worldwide Solutions ApexR5 and is the answer not in the manual?

Lighthouse Worldwide Solutions ApexR5 Specifications

General IconGeneral
Light SourceLaser Diode
Data Storage3, 000 records
Channels6
Particle Size Channels0.5, 1.0, 5.0, 10.0 µm
Display5.7 inch Color Touch Screen
CommunicationEthernet, USB
BatteryRechargeable Li-ion battery
Power Supply100-240 VAC, 50-60 Hz
Operating Temperature10° to 40°C (50° to 104°F)
Operating Humidity20% to 95% non-condensing
Measurement Range0 to 1, 000, 000 particles/ft³

Summary

EU DECLARATION OF CONFORMITY

1 General Safety

Safety Considerations

General safety precautions and warnings for operating the particle counter.

LASER Safety Information

Information on LASER safety, classification, and potential hazards.

Electrostatic Safety Information

Guidelines for preventing damage from electrostatic discharge (ESD).

2 Introduction

ApexRemote Specifications

Technical specifications for various ApexRemote models, including size, flow rate, and power.

3 Get Started

Software and SmartPort cable Setup

Steps for installing software and connecting the SmartPort cable for instrument setup.

Operation

4 Communications

ApexRemote Serial DIP Switches

Details the function of DIP switches for configuring the ApexRemote Serial model.

ApexRemote PoE Communications

How to establish communication and power for ApexRemote using PoE.

5 Maintenance Procedures

Calibration

Procedure and recommendation for annual instrument calibration.

Zero Count Test

Procedure to determine if the ApexRemote can complete zero counts successfully.

Fault Isolation

Steps for troubleshooting and diagnosing issues if the instrument fails tests.

6 Program with the MODBUS Protocol

Configuring with the MODBUS Protocol

Information on configuring the instrument parameters using the MODBUS protocol.

Changing the Default Instrument Parameters

How to modify instrument parameters like Location, Sample Time, and Hold Time.

7 Install

Appendix A ApexRemote MODBUS Register Map v1.50

Sensor Settings Registers

Description of registers used for configuring sensor-related settings.

Alarm Enable Registers

Registers for enabling or disabling alarms for particle data channels.

Enable Alarming for a Channel

Instructions on enabling or disabling alarms for individual particle channels.

Threshold Setup Registers

Registers used to configure the alarm threshold values for particle channels.

Setting the Alarm Threshold Value

Procedure for setting specific alarm threshold values for each channel.

Data Registers

Description of registers used for storing and retrieving particle count data.