If the battery voltage is at ‘Medium level’ a battery alarm beeps as long as a key is activated.
(Medium level means that battery charging is necessary to maintain the best possible lifetime).
If the battery voltage is at ‘Low level’, the battery alarm function shuts down all movement immediately. The OpenBus
TM
is still active for
approx. 15 seconds. (If trying to operate the system anyway, the battery could get deep drained or the actuator system could get damaged.
When at low battery level (which is critical), there is a risk that the processor will incorrectly monitor the end of stroke.
Crashing the actuator could be a result.
The CB16 with battery back-up only commences battery charging when it is connected to the mains.
For more information about the batteries, please contact LINAK.
Before startup of CB16OBF
Due to the microprocessor in CB16OBF the control box has to be initialised before startup.
Initialisation will in most cases be possible pressing H0 and H1 or H10 and H11 on a hand control.
Initialisation depends upon the software description so please obtain a description of the initialisation procedure from your local LINAK dealer.
If an actuator is replaced, the microprocessor always has to be initialised before use (actuators with reed / hall).
If re-programmed please ensure that the correct software is used.
Precautions
If backlight supported HB is used:
When CB16 OBL or OBF is powered by mains voltage:
- At no operation of the HB the backlight in the HB is dimmed.
- If an HB button is activated the backlight illuminates fully.
When the HB button is released the light is dimmed again after approx. 10 - 15 sec.
When CB16 OBL or OBF is powered by battery:
- At no operation of the HB theres is no backlight in the HB.
- If an HB button is activated the backlight illuminates fully.
When the HB button is released the backlight turns off.
1
st
failure safe monitoring:
Failure indication:
- all ACO LED’s are blinking
- The CB16 buzzer is shortly beeping if a hand control is activated
- The error can be reset by activating H0 and H1 OR H10 and H11 on a hand control.
Compatibility – CB16 OBL:
Using actuators with feedback on CB16 OBL are not supported. If used anyway it will not work properly. The reason is that feedback signals
(e.g. Hall signals) is positioned at the same PINS as analogue stop signals - when using no feedback.
CB16OBF SMPS - Actuator combinations and/or customized software
Due to the high power from the CB16OBF SMPS, it is highly recommended to validate the system to guarantee the lifetime of connected actuators.
Especially when using customized software and/or actuator combinations which do not comply with the LINAK compatibility list - for further
questions please contact your local LINAK contact.