ACOM is the obvious control for hospital and nursing home beds where
patient positioning needs careful control by medical staff. ACOM is an
OpenBus
TM
control.
Usage:
Operation temperature: +5 °C to + 40 °C
Storage temperature: -10 °C to + 50 °C
Relative humidity: 20 % to 80 % at +30° C, non-condensing
Atmospheric pressure: 700 to 1060 hPa
Approvals: IEC 60601-1 Edition 3.1 (2012),
IEC 60601-1-6:2010 + A1:2013
Compatibility: Compatible with LINAK OpenBus
TM
control boxes,
CO-generation
6. ACOM (MEDLINE
®
CARELINE
®
)
Recommendations
Clean the hand control regularly to ensure good hygiene standards.
When a defective ACOM is replaced, check that the new ACOM has exactly the same specification and functionality.
Do not submerge the hand control in water.
Unless otherwise specified or agreed with LINAK, the hand control is only intended to be used for LINAK systems.
When changing hand controls for OpenBus
TM
systems, the power must be switched off.
It is recommended to check the hand control and cable for damage and holes caused by violent handling before washing the application or at
least once a year.
It is recommended to have a parking place for the hand control on the application where the customer ensures that the hand control does not fall off.
Warnings:
Do not sit or lie on the hand control as this can cause unintended movement of the application.
The ACP (Attendant Control Panel) controller is fitted to advanced
hospital and patient care beds for use where patient positioning
must be carefully controlled by medical staff.
The ACP allows nursing staff to retain direct control over critical
positioning functions while giving the patient a limited degree of
adjustment.
It is recommended to clean all surfaces, also surfaces covered by lids and the inside of the lids.
(In the event that the ACP is cleaned in wash tunnels; be aware that surfaces covered by lids and the inside of lids will not be cleaned)
7. ACP (MEDLINE
®
CARELINE
®
)
The Attendant Control Touch (ACT) for the hospital and care segment is a control panel with an intuitive, graphical three-level user interface:
1. Care mode for caregivers and relatives (bed operation)
2. Extended care mode for caregivers (extended bed operation, features, settings)
3. Service mode for technicians (advanced settings)
The ACT combines several operations and functionalities in one unit, thereby eliminating the need for several hand controls on the individual bed.
In addition, the ACT is equipped with a large screen, giving the user a great overview of all the functions.
Software, graphics and front covers can be customised according to customer requirements.
The ACT supports the LINAK OpenBus
TM
system offering a high level of customisation.
Usage:
Operation temperature: +5 °C to + 40 °C
Storage temperature: -10 °C to + 50 °C
Relative humidity: 20 % to 80 %
Atmospheric pressure: 700 to 1060 hPa
Approvals: IEC60601-1
ANSI/AAMI ES60601-1
CAN/CSA-22.2 No 60601-1
Compatibility: All OpenBus
TM
control boxes
8. ACT (MEDLINE
®