    adamsclintonAug 17, 2025
    What to do if there is no motor sound or movement of piston rod in Linak Controller?
    • L
      Lisa DuncanAug 17, 2025
      If there's no motor sound or piston rod movement in your Linak Controller, first ensure the actuator is properly connected to the control box. A blown fuse in the control box could also be the cause, requiring a fuse replacement. Finally, a damaged cable could be the reason; in this case, the actuator should be sent for repair.
  • C
    clarksabrinaAug 20, 2025
    Why power indicator does not light up on Linak Controller?
    • M
      mcmahoncynthiaAug 20, 2025
      If the power indicator on your Linak Controller doesn't light up, start by ensuring it's connected to the mains. If it is, check the fuse; replace it if the system allows external fuse replacement. A defective power cable could also be the issue; if the cable is exchangeable, try a new one. If not, or if the control box is defective, the unit needs repair.
  • T
    Timothy GriffinAug 22, 2025
    How to fix motor that runs too slowly on Linak Controller?
    • O
      oblakeAug 22, 2025
      If the motor on your Linak Controller runs too slowly or lacks full force, the issue might be an insufficient power supply; try increasing it. Alternatively, a voltage drop in the cable could be the cause, necessitating a thicker cable.
  • S
    Sandra DudleyAug 26, 2025
    Why Linak Controller control box is completely dead on battery?
    • I
      igarciaAug 26, 2025
      If the control box of your Linak Controller is completely dead on battery and there's no relay clicking, the battery might be completely flat; try charging it. If charging doesn't help, the battery may be defective and needs replacement.
  • M
    Matthew WrightAug 27, 2025
    What to do if actuator does not run on battery, but relay clicking can be heard on Linak Controller?
    • E
      esparzarobertAug 28, 2025
      If the actuator doesn't run on battery, but relay clicking can be heard on your Linak Controller, ensure the actuator plug is properly pushed into the control box. If that's not the issue, the actuator might be defective and needs replacement.
  • I
    isabelblackAug 31, 2025
    Why are the control box relays clicking on Linak Controller?
    • C
      Courtney GlassAug 31, 2025
      If the control box relays are clicking on your Linak Controller, the actuator may be defective, requiring replacement. Alternatively, the control box itself could be defective and needs to be replaced.
  • R
    Richard ValdezSep 2, 2025
    How to fix motor run with quick release malfunction on Linak Controller?
    • C
      Clayton MeadowsSep 2, 2025
      If the motor runs but the quick release doesn't function or is noisy on your Linak Controller, it could be because the declutching arm turns less than approximately 75 °C. In this case, adjust the cable.
  • A
    Angela JordanSep 5, 2025
    What to do if piston rod will only move inwards on Linak Controller?
    • D
      Dr. Lucas WhiteSep 5, 2025
      If the piston rod will only move inwards and not outwards on your Linak Controller, it's possible the safety nut has operated. In this situation, send the actuator for repair.
  • R
    Robert PorterSep 8, 2025
    Why actuator cannot lift full load on Linak Controller?
    • R
      Robert LeblancSep 8, 2025
      If the actuator cannot lift a full load on your Linak Controller, it may be due to a worn clutch or a damaged motor. In either case, send the actuator for repair.
  • T
    Tommy RodgersSep 12, 2025
    What to do if motor runs but spindle does not move on Linak Controller?
    • D
      Daniel SnyderSep 12, 2025
      If the motor runs but the spindle does not move on your Linak Controller, it is likely that the gear wheel or spindle is damaged, requiring the actuator to be sent for repair.

Summary

System Description

Electrostatic Discharge (ESD) Handling

Guidelines for handling electrostatic discharge sensitive devices and customer responsibility.

IP Protection Degree

Explains IP codes for product enclosures and corresponding cleaning instructions.

Mounting Instructions

Provides instructions and torque specifications for mounting actuators, control boxes, and accessories.

Connecting the System

Details the procedure for connecting hand controls, actuators, and mains cables to the control box.

Start-up, De-installation and Operation

Troubleshooting Actuators and Electronics

Provides common symptoms, causes, and actions for resolving issues with actuators and electronics.

Specific Actuators

Specific Columns

Specific Control Boxes

CB Series Control Boxes Overview

Provides information on CB6, CB7, CB8, CB9, CB12, CB14, CB16, and CB20 control boxes.

CO Series Control Boxes Overview

Details CO41, CO61, CO65, and CO71 control boxes, including LED indicators and acoustic signals.

Specific Controls

Hand Controls (HB Series)

Covers HB20, HB30, HB40, HB50, HB60, HB70, HB80 series hand controls.

Specific JUMBO Products

Repair and Disposal

Repair Procedures

Outlines procedures for repairing LINAK actuator systems under warranty and by authorised centers.

Linak CBJ Home Specifications

General IconGeneral
Input Voltage100-240 VAC
Output Voltage24 VDC
BluetoothYes
Protection ClassIP20
Storage Temperature-10°C to +50°C

Related product manuals