The DPH is a small two button panel for adjustment of different functions. The DPH fits into a MJB with a modular plug and thereby compatible
with OpenBus
TM
.
Usage:
Ambient temperature: +5 °C to +40 °C
DPH is compatible with the OpenBox control boxes via Modular Junction Boxes MJB5061101-00 as follows:
Control Boxes: CB6S OBL, CB6S OBM, CB6S OBF, CB16 OBL, CB16 OBF, CB20
Modular Junction Box: MJB5061101-00
DPH1K10-210007 combined with MJB5061101-00 creates the OpenBus
TM
codes:
Up Arrow: H0
Down Arrow: H1
Wrong mounting is not an issue with the MJB5061101-00 and the modular jack plug of the DPH cable.
The plug will only fit into the correct ports of the MJB.
9. DPH Medical (MEDLINE
®
CARELINE
®
)
Recommendations
The application manufacturer must insure a proper installation of the FPP in the application. The installation must be convenient for the end-user.
To ensure proper activation, the lock above the housing must be properly locked by turning it clockwise.
The application manufacturer must ensure the correct torque to the slotted set screw at the bracket, to ensure a stable positioning of the FPP.
The application manufacturer must consider the bracket location for the FPP: If the FPP is mounted at a moveable part, it will move and might
touch the patient or parts of the application. If mounted at a fixed part, the patient might move out of range to reach the FPP or he might even be
hit by the FPP.
The end-user must not apply a torque to the FPP housing exceeding 8 Nm between the flexible arm and the panel.
The end-user must not bend the FPP arm to a radius smaller than 105 mm.
The FPP must not be useed as a handle at any time when moving the application.
The end-user must be informed that the FPP must not be used for other purposes (e.g. table, handle) than intended, i.e. as a Flexible Patient Panel (FPP).
The end-user must ensure the FPP does not hit items or persons when the application is moved.
The FPP is for use with a variety of different bed types and is therefore compatible with control boxes that use
an OpenBus™ interface i.e. CB6S, CB16 and CB20.
Usage:
Ambient temperature: +5 °C to +40 °C
Approvals: LINAK and UL International DEMKO A/S are currently in the process of certifying
FPP re. UL60601 and EN60601-1.
Current consumption: 15 mA (Standard versions with 5 no. LED’s (5 LED’s x 2 mA = 10 mA) +
microprocessor 5 mA, total = 15 mA
10. FPP (MEDLINE
®
CARELINE
®
)
Mounting instructions:
The FPP is intended for mounting at the head end of a bed so the patient is able to see and operate it with an easy push of a button. After use it can
be moved a short distance away with an easy movement.
The FPP comes with a cable attached. The bottom part of the arm is prepared for mounting inside a bracket - fitting the diameter of the arm.
The bracket is not supplied by LINAK but must be designed and made by the customer. It must fit the dimensions shown. A suggestion to a design is
illustrated on below pictures as well as the dimensions of the parts for fixation.