Lifting Column LC3 IC | 11
Use 4 pcs� M10 8�8 bolts at each end of the column for mounting to the application�
The screw depth must be min� 20 mm and max� 30 mm in the aluminum profile�
Screw torque: 35 Nm�
A
A B
B
146 0.5
146 0.5
101 0.5
101 0.5
43 0.5
163 1
129 1
146 1
4315
M10x1.5
30
M10
30
REP = STANDARD-SBU
B-B
SECTION A-A
MIN.90MIN.60
(M8) 146
(M6) 144 -146
(M5) 143 -146
(M4) 142 -146
M8
Drill-Max. 16
Thread-Max 14
M6
Drill-Max. 15
Thread-Max 13
M5
Drill-Max. 13
Thread-Max 11
M4
Drill-Max. 12
Thread-Max 10
½ S + 280mm (HEAVY DUTY)
Created By Pamir Hamid 2022-07-07
Modified By Pamir Hamid 2022-07-11
SCALE : 1:5
Drawing No.: TEC-0001888
SECTION C-C
C
C
M10x1.5 M10x1.5
15 mm distance to thread Bolt depth min. 20 mm 43 mm distance to thread
Mounting holes
A
A B
B
146 0.5
146 0.5
101 0.5
101 0.5
43 0.5
163 1
129 1
146 1
4315
M10x1.5
30
M10
30
REP = STANDARD-SBU
B-B
SECTION A-A
MIN.90MIN.60
(M8) 146
(M6) 144 -146
(M5) 143 -146
(M4) 142 -146
M8
Drill-Max. 16
Thread-Max 14
M6
Drill-Max. 15
Thread-Max 13
M5
Drill-Max. 13
Thread-Max 11
M4
Drill-Max. 12
Thread-Max 10
½ S + 280mm
Created By Pamir Hamid 2022-07-07
Modified By Pamir Hamid 2022-07-11
SCALE : 1:5
Drawing No.: TEC-0001888
SECTION C-C
C
C
M10x1.5 M10x1.5
A
A B
B
146
0.5
146 0.5
101 0.5
101 0.5
43 0.5
163 1
129 1
146 1
4315
M10x1.5
30
M10
30
REP = STANDARD-SBU
B-B
SECTION A-A
MIN.90MIN.60
(M8) 146
(M6) 144 -146
(M5) 143 -146
(M4) 142 -146
M8
Drill-Max. 16
Thread-Max 14
M6
Drill-Max. 15
Thread-Max 13
M5
Drill-Max. 13
Thread-Max 11
M4
Drill-Max. 12
Thread-Max 10
½ S + 280mm
Created By Pamir Hamid 2022-07-07
Modified By Pamir Hamid 2022-07-11
SCALE : 1:5
Drawing No.: TEC-0001888
SECTION C-C
C
C
M10x1.5
M10x1.5
It is recommended to use bolts with thread-lock adhesive
Bolts of high quality steel 8�8 or 10�9 must be used to secure safe mounting of the LC3 IC to the
application�