Lifting Column LC3 IC | 16
Electrical installation
When using soft stop on a DC motor, a short peak of high voltage will be sent back towards the power
supply� When selecting the power supply, it is important to ensure that is does not turn off the output,
when this backwards load dump occurs�
Depending of option there can be three different connectors on the LC3 IC Lifting Column:
The most left is the power connector for a 24 V DC power supply, a cab0367046-xxxx cable fits the
connector
In the middle there is a 9-pin signal connetor for controlling the LC3 IC and gathering information
regarding position and end stop signals� The cab0368543-xxxx cable that fits the connector should be
connected to a PLC or cobot controller
The connector to the most right is a RJ-45 for Modbus TCP/IP, a shielded (STP) cat 6 ethernet cable or a
cable with a category according to the requried transmission speed can be used with this connector
The ethernet cable is not supplied by LINAK
The signal connector offers access to Actuator Connect�