45
Multiple pumps are created by combining individual pump units in series, with the pumps arranged by capacity. Positioning the
gear pump(s) at the end of the unit ensures optimum space utilization, output allocation and load distribution. The following table
is based on the gear pump acting as boost pump for the HPV-02 variable pump.
Dimensions. Multiple pumps
L1
L2
L3
rear pump front pump
Overall length of multiple pump HPR-HPV-02
Multiple pump HPR-HPV-02
Rated size Rear pump HPV 55 HPV 75 HPV 105 HPV 135 HPV 165 HPV 210 HPV 280
Front pump Charge pump 16 cc/rev 22.5 cc/rev 22.5 cc/rev 22.5 cc/rev 38 cc/rev 38 cc/rev 38 cc/rev
HPR 55
L1 493 - - - - - -
L2 553 - - - - - -
L3 607 - - - - - -
HPR 75
L1 504 521 - - - - -
L2 569 586 - - - - -
L3 624 641 - - - - -
HPR 105
L1 525 542 567 - - - -
L2 590 607 632 - - - -
L3 645 662 687 - - - -
HPR 135
L1 541 558 583 623 - - -
L2 601 623 648 688 - - -
L3 676 678 703 763 - - -
HPR 165
L1 584 601 626 683 715 - -
L2 759 776 801 858 890 - -
L3 834 851 876 933 965 - -
HPR 210
L1 605 622 647 704 736 749 -
L2 780 797 822 879 911 924 -
L3 855 872 897 954 986 999 -
HPR 280
L1 674 691 716 730 762 788 834
L2 849 866 891 905 937 963 1009
L3 924 941 966 980 1012 1038 1048