EasyManua.ls Logo

Linear AE-500 User Manual

Linear AE-500
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
(760) 438-7000
USA & Canada (800) 421-1587 & (800) 392-0123
Toll Free FAX (800) 468-1340
www.linearcorp.com
AE-500
Telephone Entry
& Access Control
System
220793 F IMAGE 1
PRINTER’S INSTRUCTIONS:
INSTR,INSTL,AE-500 - LINEAR P/N: 220793 F - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 8.500” X 11.000” - SCALE: 1-1 - FOLDING: ALBUM-FOLD - BINDING: SADDLE-STITCH
Installation Instructions

Other manuals for Linear AE-500

Question and Answer IconNeed help?

Do you have a question about the Linear AE-500 and is the answer not in the manual?

Linear AE-500 Specifications

General IconGeneral
BrandLinear
ModelAE-500
CategoryIntercom System
LanguageEnglish

Summary

System Capabilities Overview

Hardware Features

Lists physical attributes of the AE-500 system and its components like radio receiver, relays, and inputs.

Software Highlights

Lists key software functionalities and programming options such as local and remote programming, and code capacities.

Remote Keypad Support

Describes compatibility with optional interior and exterior keypads for expanded access control.

Feature Overview

Access Control Functions

Details relay outputs, request-to-exit inputs, sensing inputs, keypads, postal lock, camera, and obstacle detection.

System Configuration and Power

Covers built-in modem, programming methods, and battery backup for system operation.

Database Structure Overview

Explains how resident, entry code, and transmitter data is stored and managed by the system.

Component Locations

Front Panel Identification

Identifies external components visible on the AE-500 unit's faceplate.

Internal Component Layout

Maps internal circuit board components, connectors, and adjustments for installation and service.

Wiring Diagrams

Power and Relay Connections

Illustrates how to wire the power supply, transformer, and relay outputs for access devices.

Input and Telephone Line Wiring

Shows connections for request-to-exit inputs, sensing inputs, and the main telephone line.

Mounting Requirements and Guidelines

Installation Site and Environmental Factors

Covers location choice, building codes, vehicle traffic, and ADA compliance for optimal installation.

Gate Installation Specifics

Provides distance and safety guidelines for mounting the unit when controlling vehicular gates.

Entry System Mounting Procedures

Surface Mounting Installation

Details steps for mounting the AE-500 unit directly to a wall or flat surface.

Pre-Mounting Preparation

Outlines steps for preparing the unit, including removing the circuit board, before installation.

Additional Mounting Options

Recessed Wall Mounting

Explains how to install the AE-500 unit recessed into a wall using an accessory trim-ring.

Pedestal Mounting

Describes the procedure for mounting the unit on a standard goose-neck pedestal.

Relay Output and Input Wiring

Connecting Door and Gate Controls

Details wiring for door strikes, magnetic locks, and gate operators using relay outputs.

Request-to-Exit and Sensing Input Wiring

Covers wiring for exit request buttons and door sense/access inhibit inputs.

Power, Battery, and Ground Wiring

Electrical Power and Backup Connections

Covers AC power wiring, optional DC backup battery connections, and earth ground.

CCTV Camera Wiring and Installation

Details connecting the optional Linear Model CCM-1 CCTV camera to the AE-500.

Telephone and Radio Connectivity

Telephone Line Setup

Guides on connecting the AE-500 to a standard telephone line for entry and programming.

Radio Antenna Installation and Tuning

Covers installing radio antennas and adjusting receiver range for optimal transmitter reception.

Optional Accessory Installation

Postal Lock Installation Procedure

Explains how to install a U.S. Postal Service lock for keyed access.

Remote Keypad Installation Procedure

Details installing optional Linear AM-KP or AM-KPI remote keypads.

Computer Programming Setup

Establishing Internet Connection for Programming

Guides through setting up a dial-up connection in Windows XP for AE-500 programming.

Accessing the AE-500 Web Interface

Explains how to connect via modem and access the AE-500's web-based programming interface.

System Programming Methods

Programming via Telephone

Details using a TouchTone telephone keypad to program the AE-500 system.

Programming via Local Keypad

Explains using the AE-500's on-unit keypad for system setup and programming.

Programming Reference and Data Management

Programming Parameter Reference

Lists Programming Parameter Numbers (PPNs) and their corresponding factory settings.

Factory Settings and Data Backup

Covers default system settings and procedures for backing up and restoring data.

Multi-Unit Setup and Password Management

Configuring Multiple AE-500 Units

Guides on assigning unique unit numbers for multi-unit installations over the same telephone line.

Changing the Master Password

Details the procedure for changing the six-digit master password for system security.

Resident Data Management

Directory Number Configuration

Sets the length for resident directory numbers, from 2 to 4 digits.

Resident Record Operations

Covers adding, modifying, and deleting resident names and telephone numbers.

Entry Code Management

Entry Code Length Configuration

Sets the length for entry codes, from 2 to 6 digits.

Entry Code Operations

Covers adding, modifying, and deleting entry codes with relay assignments and usage limits.

Wireless Transmitter Operations

Assigning Transmitters to the System

Covers assigning transmitters in blocks or individually, including facility codes.

Managing Transmitter Status

Details suspending, activating, and deleting individual wireless transmitters.

System Options - Display and Relay Configuration

Display and Keypad Settings

Configures display language, keypad lockout count, and relay activation times.

Relay Activation and Functionality

Sets relay activation time and configures the function of Relay Channel 'B'.

System Options - Input and Key Assignments

Sensing Input Configuration

Sets the sensing input for door sense or access inhibit functionality.

MGT Obstacle Transmitter Setup

Configures the obstacle transmitter status, facility code, and ID number.

Resident Telephone Key Assignments

Customizes resident telephone keys for granting access or disconnecting calls.

System Options - Display and Audio Settings

Welcome Message Configuration

Customizes the welcome message displayed on the AE-500's two-line display.

Audio and Answering Settings

Configures automatic telephone answering, speaker chirps, and relay activation tones.

System Options - Visitor and Transmitter Settings

Visitor Call Duration and Directory Display

Adjusts maximum visitor talk time and the starting position of the directory list.

Transmitter Button Customization

Defines the actions assigned to single and multi-button transmitter functions.

System Utilities and Maintenance

System Information Display

Shows the AE-500 unit number and system firmware version.

Relay Control and Data Management

Allows manual relay control, deletion of database entries, and total memory reset.

System Adjustments and Diagnostics

Audio and Display Calibration

Adjusts tone volume, speaker volume, and display contrast for optimal user experience.

System Status Indicators and Restart

Explains the function of on-board LEDs and the system restart button.

AE-500 Operation Modes

Accessing via Entry Code

Describes how authorized personnel use entry codes to gain access.

Accessing via Wireless Transmitter

Explains how to use wireless transmitters to activate relay channels for access.

Visitor Call and Resident Interaction

Details the process of visitor calls, two-way communication, and resident control of access.

Specifications and Troubleshooting

System Specifications Summary

Lists technical details including mechanical, electrical, radio, environmental, and system parameters.

Common Troubleshooting Scenarios

Provides solutions for common issues like system dead, buzz on speaker, and failed relay activation.

Warranty and Regulatory Information

Linear Limited Warranty Coverage

Details the warranty terms, duration, and limitations for the AE-500 product.

FCC Compliance and Interference Guidelines

Explains FCC rules for Class B digital devices and measures to mitigate radio interference.

Related product manuals