Cross-flow fan unit type GSG-NV1 / 2
010980-26-E BA GSG-NV1_2 / 23.03.2012
15.4. Nozzle selection and distribution quantity
The LIPCO GSG-NV is equipped with green ALBUZ AVI 80° flat
fan venture nozzles. (Other nozzles are available on request.)
During installation make sure
that the seal is properly
mounted before the fan noz-
zle.
Seal
It is recommended that the
nozzle body be swiveled up-
ward for assembly in perpen-
dicular position.
Determining the distribution quantity in l/min. from nozzle inserts
in drip-stop nozzle bodies.
Distribution
quantity of
one nozzle
in l/m
Number of all open nozzles
The choice of required nozzles is based on the following nozzle
charts. For the same nozzles, the discharge of liquid from the
LIPCO GSG-NV corresponds to the product of the number of
nozzles X single nozzle discharge.
ALBUZ AVI 80° flat fan venturi nozzle
(1 bar = 0.0689 lbf/in²)
If the unit is equipped with different nozzles, the discharge of all
single nozzles must be added together. Please note that oppos-
ing nozzles must be identical.