EasyManua.ls Logo

Lipco GSG-NV Series - Page 31

Lipco GSG-NV Series
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating Manual
Cross-flow fan unit type GSG-NV1 / 2
31 - 64
010980-26-E BA GSG-NV1_2 / 23.03.2012
If necessary, engage the sprayers until liquid is discharged even-
ly from the nozzles.
Switch off the LIPCO GSG-NV and again fill the tank to the se-
lected marking on the filling mandrel.
Conduct a spray text for at least 2 min.
Determine the volume of liquid used by refilling to the marking
and then compare with the calculated total discharge. (For
smaller amounts or to increase the accuracy of the measure-
ment, it may be necessary to spray for a longer duration.)
In case of deviations, correct the spray pressure and repeat the
procedure. Higher pressure results in a greater discharge of liq-
uid and vice versa.
Record the results in writing.