142
Keypad
Display
Error Name
Cause
Possible Solution
Note: If C6-03 6 , the drive
operates at C6-01
2. The limit set in C6-00 to C6-
03 are contradictory
oPE12
Analog Frequency
Command Hold Error
When E1-□□=61, there is
another E1-□□ is set to 10 to
13, 18 or 53 to 55.
Correct the setting.
oPE13
main and Alternative
Frequency
Command Error
When b1-00 and b1-07 are
setting the same supply source
Correct the setting.
oPE14
Incorrect Jump
Frequency Setting
The setting does not follow L3-
00 L3-01 L3-02
Correct the setting.
oPE15
Retain
oPE16
Retain
oPE17
Motor Rated Speed
Setting Error
1. Motor rated speed setting
over the motor synchronous
speed
1. Set the motor base frequency and
the correct number of motor poles
2. Correctly set the motor rated
speed
Motor synchronous speed = 120
base frequency / motor pole number
oPE18
Retain