EasyManua.ls Logo

LiteOn EVO 6800 Series - Page 166

LiteOn EVO 6800 Series
169 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
163
Appendix UL Description
1) “Maximum surrounding air temperature rating of 50ºC for Open Type; 40ºC for UL
Type 1”
2) “The drive is suitable for use in a circuit capable of delivering not more than
5,000 rms symmetrical amperes, 480 Volts Maximum.”
These devices are only intended to be installed with the following branch circuit
fuse.
440V
HD Mode
HP
MotorKW
INV
Line Fuse
Input Current (A)
Rate Current (A)
Bussmann P/N
0.5
0.4
2.2
10
JJS-10
1
0.75
4.1
15
JJS-15
2
1.5
5.1
20
JJS-20
3
2.2
6.6
30
JJS-30
5
3.7
11.4
45
JJS-45
7.5
5.5
15.2
60
JJS-60
10
7.5
25.1
60
JJS-60
15
11
34
60
JJS-60
20
15
38.4
125
JJS-125
25
18.5
45.6
150
JJS-150
30
22
58.5
200
JJS-200
40
30
78
250
JJS-250
50
37
85
250
JJS-250
60
45
102
350
JJS-350
75
55
125
400
JJS-400
100
75
150
500
JJS-500
125
90
180
600
JJS-600
150
110
210
700
KTU-700
440V
ND Mode
HP
MotorKW
INV
Line Fuse
Input Current (A)
Rate Current (A)
Bussmann P/N
0.5
0.4
2.8
10
JJS-10
1
0.75
5
15
JJS-15
2
1.5
6.5
20
JJS-20
3
2.2
9.6
30
JJS-30

Other manuals for LiteOn EVO 6800 Series