EasyManua.ls Logo

LiteOn EVO 6800 Series - Page 65

LiteOn EVO 6800 Series
169 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
62
For digital inputs, switch Sink /
Source mode must be external
connection
S7C
High-speed pulse signal common terminal
COM
Digital control signal common terminal
Multi-Function
Analog Inputs
+V
Auxiliary power terminal +10V
Analog input power+10V
A1
Analog input terminal 1
(main frequency command)
Voltage input
0 to 10V / -10V to +10V
A2
Analog input terminal 2
(auxiliary frequency command)
Voltage or current input
(Selectable). 0 or 4 to
20mA, 0 to 10V, 0 to 5V
PE
Ground terminal
The ground terminal for
control signals to avoid
interference. Use shielded
cables only.
24V
+24V auxiliary power terminal for analog input
Digital control signal
power + 24V
(INT port selection by
short-circuiting)
INT: short circuit, internal
offer
+ 24V / 200mA: open,
externally supplied + 24V
Table 4.3.1.2 Control Circuit Output Terminals
Terminal Type
Terminal
Code
Terminal Name
Terminal Description
Multi-Function
Photocoupler
Output
D1
Photocoupler Output terminal 1 (zero speed)
Photocoupler Output
48 V, 2 to 50 mA
D2
Photocoupler Output terminal 2 (speed agree)
D+
RS485 communication terminal, standard RS485 interface, use twisted pair or
shielded wire
D-
Multi-Function
Analog Output
FM
Programmable analog output terminal (output
frequency)
Voltage Output
0 to 10V, -10 to +10V
AM
Multi-function analog output terminal (output
current )
Voltage or current output
(Selectable) 0 or 4 to
20mA, 0 to 10V
AC
Analog common terminal
Multi-Function
Pulse Train Output
MP
Multi-function pulse train output (output
frequency)
50KHz Max
<1> Do not assign frequent switching functions such as ON/OFF to terminals R1 and R2, which may