6
Failure:
Termination of the ability of an item to perform a required function
Note 1: After failure the item has a fault
Note 2: "Failure" is an event, as distinguished from"fault", which is a state.
Note 3: This concept, as dened, does not apply to items consisting of software only.
Note 4: In practice,the term fault and failure are often used synonymously
Self-checking:
The device switches automatically into the "safe state" when it is faulty
.
Standard Mounting Range:
Maximum distance between transmitter and receiver is 5 m, if exceed
the distance may lead to hazardous motion. For longer range please get
in contact with us.
Overrun Distance:
The distance covered during the overrun (e.g. by the ram of a press).
Start Interlock:
After initial operation or after a power supply interruption a renewed
"enabling" is blocked by the start interlock.The renewed release of the
switching unit is only possible by closing and opening of the start entry.
Box Bending Mode:
The E3 is muted during during bending process.
2.2 Usage
SLA-3 is the safety device specially applied to bending machine for
operator's protection which adpoted class 1 laser, A three-dimension
laser protective eld between the emitter and receiver to form the
guarding area underneath the clamped upper tool, any intervention into
the area shuts down the closing movement of the press.