Function (04) Shunt Time
Setting of relay's ON/OFF time in the proximity reader can be set from 0-255 seconds.
Set 000 as toggle function as the door is always open until the next proximity.
(default value as 003 )
Function (05) Door Open Mode
Reader has 2 types of identification modes. (default value as 2 )
Mode (2). Card proximity door open: The door opens, when the card is sensed.
Mode (3). Door open by proximity card and password: The door opens by entering
additional 4-digit password after sensing the registered card.
Enter shunt time(0~255)
Enter
# system password #
Enter # to go
Enter # to go
back to system function selection.
back to system function selection.
Enter to clear.
It goes back to system function
selection when nothing is entered.
Enter to goes back to
system function.
Enter door open mode(2 or 3)
Enter
# system password #
Enter 4 #
Enter 5 #
4
00
5
2
Display
Display
Display
Display
7