3. Technical Data
3.1 Energy Requirements
Input Power: 85-264 VAC, 50-60 Hz
Power Draw: 150 Watts
Inrush Current: 3 Amps
3.2 Dimensions (LED Controller)
Width: 10 inches
Depth: 9 5/8 inches
Height: 3 7/8 inches
Weight: 8 lbs
3.3 Dimensions (CureJet
TM
)
Width: 1 inch
Depth: 10 1/8 inches
Height: 2 1/2 inches
Weight: 1 lb
3.4 UV Output Characteristics 375 Units(UV) 405 Units Indigo
TM
Units
Typical Output *: >4 W/cm
2
> 4W/cm
2
>4 W/cm
2
Spectral Output Range: 375-380 nm 390 – 420 nm Proprietary
Primary Peak: 375 nm 405 nm Proprietary
3.5 Operating Conditions
Max Operating Environment Temperature Approx 90
o
F (55
o
C)
Max Operating Environment Humidity 85% RH
(*Exact output measurement is dependent on the brand and calibration method of the meter used.
These measurements were made with the Loctite
®
UV-B&A LED Qualified Radiometer P/N 1390323
(375 Units) and Visible Light LED Dosimeter, P/N 1265282 (405 Units & Indigo
TM
Units).