E60 ISP Activated
Release all Keys and wait for the Drive Back function to be
completed.
E61 Motor Replaced
Plug in the correct motor. Ensure all cables are connected
correctly. Perform a Factory Reset. Perform a Position Reset
Procedure.
E65 Overcurrent while driving
Check that nothing is blocking the table's range of movement.
Remove excess load from the table. Contact LOGICDATA for
further information.
E67 High Voltage Detected
Disconnect the Control Box from the Mains. Contact
LOGICDATA for further information.
E70 Motor Conguration Changed
Disconnect the Control Box from the Mains. Connect the
Actuators in the desired setup. Perform a Factory Reset.
Perform a Position Reset Procedure. Read Chapter 9,
"Actuator Setup", for advice on changing Actuator types.
E71 Collision Sensor Defective
Perform a Factory Reset. Contact LOGICDATA if the problem
persists.
E72 Position Error (Middle Switch*)
Disconnect the Control Box from the Mains. Wait for at
least 20 seconds. Reconnect and perform a Position Reset
Procedure.
E73 Middle Switch* Defective
Disconnect the Control Box from the Mains. Contact
LOGICDATA for further information.
E81 Internal Error
Disconnect the Control Box from the Mains. Restart and per-
form a Factory Reset. Contact LOGICDATA for further infor-
mation if the problem persists.
E90
Cascading error (slave)
Check all connections. Attempt a Position Reset Procedure.
If this is not possible, disconnect all Control Boxes from the
Mains and try again. Contact LOGICDATA for further infor-
mation if the problem persists.
E91
E92
E93
Connection Error During
Cascading
Check all connections. Attempt a Position Reset Procedure.
If this is not possible, disconnect all Control Boxes from the
Mains and try again. Contact LOGICDATA for further infor-
mation if the problem persists.
NOTICE
Do not operate the table system if problems persist. Contact LOGICDATA for further
information.
NOTICE
The Middle Switch is only tted to certain versions of the SMARTneo-2G. Contact
LOGICDATA if you are unsure which version you have.

Table of Contents

Other manuals for LOGICDATA SMARTneo-3G

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LOGICDATA SMARTneo-3G and is the answer not in the manual?

LOGICDATA SMARTneo-3G Specifications

General IconGeneral
BrandLOGICDATA
ModelSMARTneo-3G
CategoryControl Unit
LanguageEnglish

Related product manuals